Water quality criteria

Designated-Best-Use

Class of water

Criteria

Drinking Water Source without conventional treatment but after disinfection

A

  • Total Coliforms Organism MPN/100ml shall be 50 or less
  • pH between 6.5 and 8.5
  • Dissolved Oxygen 6mg/l or more
  • Biochemical Oxygen Demand 5 days 20°C 2mg/l or less

Outdoor bathing (Organised)

B

  • Total Coliforms Organism MPN/100ml shall be 500 or less pH between 6.5 and 8.5 Dissolved Oxygen 5mg/l or more
  • Biochemical Oxygen Demand 5 days 20°C 3mg/l or less

Drinking water source after conventional treatment and disinfection

C

  • Total Coliforms Organism MPN/100ml shall be 5000 or less pH between 6 to 9 Dissolved Oxygen 4mg/l or more
  • Biochemical Oxygen Demand 5 days 20°C 3mg/l or less

Propagation of Wild life and Fisheries

D

  • pH between 6.5 to 8.5 Dissolved Oxygen 4mg/l or more
  • Free Ammonia (as N) 1.2 mg/l or less

Irrigation, Industrial Cooling, Controlled Waste disposal

E

  • pH betwwn 6.0 to 8.5
  • Electrical Conductivity at 25°C micro mhos/cm Max.2250
  • Sodium absorption Ratio Max. 26
  • Boron Max. 2mg/l

 

Below-E

Not Meeting A, B, C, D & E Criteria

Source : www.cpcb.nic.in